Your current location:Home - About us - News centerThe 1-in 3-out layout is deliberately plain. One port is designated as the trunk input and three ports are outputs, each feeding one device. In the Ximeconn CAN BUS 3-way M12 distributor, that structure sits inside a single molded body rated IP67, fitted with M12 threaded couplings and rated for a -40°C to +85°C working range. The published electrical rating is 250V AC/DC at 4A, which places the part firmly in signal and low-power auxiliary supply territory rather than power distribution. Each element of the structure does a specific job in a field scenario:
• The trunk input port converts a long home run into a local distribution point, so the cable that took the most effort to route terminates at a labelled socket on the machine frame instead of a terminal strip behind a cabinet door.
• The three output ports each carry a single device drop, which lets a sensor cluster, a valve manifold and a maintenance socket share one trunk connection without plugs being chained through one another in mid-air.
• The M12 threaded coupling holds the contact pair together under vibration and presses the seal faces closed, which matters on presses, transfer lines and anything with a motor bolted nearby.
• The sealed housing keeps the branch point out of an enclosure, so the split happens on the machine where the devices are rather than inside a box that needs its own door, gasket, footprint and cable entries.
Read the port labels as installation guidance rather than electrical direction. On a shared bus, frames travel both ways through the junction, and every device on the segment sees the traffic; the controller identifier decides who responds. What the labelling really delivers is a clean mental map for the technician: trunk here, devices there, three at a time. The 250V AC/DC and 4A figures set the practical envelope. That is comfortable for bus conductors plus a low-power auxiliary feed to a sensor or a small actuator, and it is the wrong tool for a motor branch or a main power feed, which belongs in its own circuit with its own protection.